MODEL HP30
2-circuit
2-circuit
Designed to be used when 2 independent heating circuits are needed for heating one large room. Programmable.
Temperature Range: 40°F – 93°F (4°-34°C)
Temperature Default: Programs Set Point
Display Format: LCD
Display Size: Large Format
Illumination: Seattle blue, on touch of key
Sample Rate: Every 60 seconds
Delay On: 1 second for relay 2
Heat Indicator: LCD “heater On”
Relay Rating: 16 Amps x (2) resistive or inductive
Relay: AA battery powered
Mounting: 2×4 electrical box
Accuracy: ± .9°F
Maximum Amps: 16 resistive or inductive
Maximum Watts per Pole:
7700 @ 240V
6656 @ 208V
3840 @ 120V
Minimum Watts: 0
Power Supply:
1 to 240 Volts AC
1 to 30 Volts DC
Installation: Leveling of the thermostat is not required. Mounting screws are provided. Mount the thermostat about five feet above the floor in an area with good air circulation. Avoid mounting the thermostat where it will be affected by drafts, air from ducts and radiant heat sources such as appliances, the sun or plumbing pipes. Typically the best location is above a light switch for that room.